INTERACTIVE ENGINEERING TOOLS
NFC Engineering & Reader Migration Tools
Run instant format checks, replacement matching and server receiver templates locally in your browser. Zero card UIDs or credentials leave your device — carry verified requirements straight into a sample or project quote.
01 · UID & FORMATS
NFC UID Byte-Order, Wiegand & Excel Safe-Text Converter
Check why the same 4-byte or 7-byte NFC card produces different numbers across access-control panels, PC/SC tools and spreadsheets.
| Output format | Calculated value |
|---|---|
| Hexadecimal (MSB → LSB normal order) | 04A1B2C3D4E5F6 |
| Hexadecimal (LSB → MSB byte-reversed) | F6E5D4C3B2A104 |
| Zero-padded decimal (normal byte order) | 01303689068602870 |
| Zero-padded decimal (reversed byte order) | 69495546249912580 |
| 26-bit Wiegand payload (lower 3 bytes) | FC 212, ID 58870 |
| 34-bit Wiegand payload (lower 4 bytes) | FC 50132, ID 58870 |
| Excel leading-zero safe formula (Hex) | ="04A1B2C3D4E5F6" |
| Excel leading-zero safe formula (Decimal) | ="01303689068602870" |
Arithmetic preview only. Confirm exact firmware output mode, prefix/suffix delimiters and card protocol with a sample card before deployment.
02 · LEGACY & EOL MIGRATION
30-Second Reader Replacement & Interface Matcher
Moving off discontinued desktop readers or standardizing a new OS stack? Select your current reference model, host OS and software layer.
Matches standard USB CCID / PC/SC smart-card workflows without proprietary SDK lock-in. Verify your exact APDU sequences and ISO/IEC 15693 requirements on a sample unit.
Third-party names are used strictly to identify integration scenarios. Drop-in behavior depends on your exact APDU commands, driver rules and card type — always validate 1 sample unit first.
03 · NETWORK WEBHOOK & MQTT
Network Reader Event Receiver Code Generator
Generate clean, open-protocol HTTP POST or MQTT subscriber starter templates with 3-second duplicate-tap filtering for PR-501, PR-502 and PR-503.
// Standard HTTP event receiver template for PR-503 (verify payload fields on your selected firmware)
import { createServer } from 'node:http';
const seen = new Map(); // Deduplicate repeated card-present events within 3s
createServer((req, res) => {
if (req.method !== 'POST' || req.url !== '/nfc/events') { res.writeHead(404).end(); return; }
let body = '';
req.on('data', chunk => { if (body.length < 8192) body += chunk; });
req.on('end', () => {
const event = JSON.parse(body || '{}');
const key = `${event.device_id ?? 'PR-503'}:${event.uid ?? ''}`;
const now = Date.now();
if ((seen.get(key) ?? 0) + 3000 < now) { seen.set(key, now); console.log('Card event:', key); }
res.writeHead(200, { 'content-type': 'application/json' }).end(JSON.stringify({ status: 'ok' }));
});
}).listen(8080); Pre-deployment sample verification points
- Confirm exact JSON field names and HTTP/MQTT mode on the selected firmware revision.
- PR-503 supplies wired Ethernet without built-in PoE by default; specify external PoE splitter needs when quoting.
- Test LAN cable disconnect, broker restart and duplicate-tap idempotency with real project cards.
04 · NDEF & MEMORY BUDGET
NFC Tag Memory & NDEF Payload Byte Calculator
Calculate exact UTF-8 payload bytes, URI prefix compression and Type 2/Type 5 TLV framing overhead before choosing a tag class and PR writer.
| Tag memory class | User bytes | Fit & headroom |
|---|---|---|
| 144 B class (NTAG213 / Type 2 entry) | 144 B | Fits · 91 B free |
| 504 B class (NTAG215 / Type 2 standard) | 504 B | Fits · 451 B free |
| 888 B class (NTAG216 / ISO 15693 high-density) | 888 B | Fits · 835 B free |
| 4096 B class (DESFire EV2/EV3 4 KB file) | 4096 B | Fits · 4043 B free |
Framing reflects single-record NFC Forum Type 2/Type 5 TLV layout without custom lock or signature bytes. NFCDock supplies reader-writer hardware only; verify exact tag memory maps with a sample card.
05 · OEM ENCLOSURE & CABLE CHECK
OEM Metal Bezel, USB Cable & Power Readiness Checker
Pre-check 13.56 MHz metal-cutout clearance, cabinet USB cable EMI risk and Ethernet power budgets before freezing sheet-metal or plastic tooling.
READY FOR BENCH SAMPLE
- Non-metallic window with >= 15 mm perimeter clearance preserves 13.56 MHz antenna tuning.
- Catalogued PR-106, PR-203 and PR-403 are USB OEM modules; request TTL UART or RS232 variants separately if your host lacks USB.